Frame or chassis terminal this w arning sign denotes a hazard. For additional information about firmware revisions, see appendix a. For more information about handheld capacitance and lcr meters, please visit keysight u1700 series handheld capacitance and lcr meters. Lcr8000g series user manual 16 front panel overview lcr8101g dc, 20 1m hz precision lcr meter menu h f m m. For additional important information about serial numbers, read.
A wide variety of handheld lcr meter options are available to you, such as auto testing machine. Digital handheld lcr meter quality rlc meter 100khz 10khz. In the simpler versions of this instrument the impedance is measured internally and converted for display to the corresponding capacitance or inductance value. Discharge all charging elements, such as capacitors, before testing. U1733c 100hz120hz1khz10khz100khz handheld lcr meter. An lcr meter is a piece of electronic test equipment used to measure the inductance l, capacitance c, and resistance r of a component. Gain better noise immunity and save money with smd tweezer option. Design and fabrication of inductors for induction heat. Lutron electronics lcr9184 operation manual pdf download. Model name lcr915 agilent u1732c main display 20,000 count 20,000 count analog bargraph displayanalog bargraph display 46 segments46 segments 25 segments25 segments. U1731cu1732cu1733c users guide v warning use this meter only as specified in this manual. Lawyers guide to the language of data storage and networking. The chroma 1102111021l are the most costeffective digital lcr meters, providing 100hz, 120hz, 1khz, and 10khz test frequencies for the 11021 and 1khz, 10khz, 40khz, 50khz test frequencies for. At the bottom of the box was the original instruction manual written in, i dunno, taiwanese.
The power for the meter is supplied with a single standard 9v battery. The de5000 uses kelvin connections and the ability to calibrate out test lead offsets. This lcr meter features automatic lcr selection, a sorting mode, and selectable test frequencies. Lcrii overview this manual provides instructions for the initial setup, the calibration, and the operation of lectrocount lcrii sof tware, also known as sr260 firmware. Other useful information would include your experience with similar products, infomation on a product that you would purchase instead of this one, and so on. Accurate and fast measurements may be made from 20hz to 1mhz 43100 making the 4300 series the ideal choice for many applications in the test or production environments. It also offers multiple test frequencies that are selectable. Agilent 4263b lcr meter operation manual serial numbers. Confirm that the circuits have been powered off and all capacitors in the circuits been discharged before measuring incircuit components. Oct 21, 2014 precision lcr meter lcr800 user manual gw instek part no. Trig k d q s v a p n discharge test device before connecting lforce lsense hsense hforce code clear enter local main display function keys local key menu key single repetitive key calibration key unit keys trigger key arrow. Deree de5000 instruction manual pdf download manualslib.
Do not block or obstruct the cooling fan vent opening. Lcr 6000 series user manual i safety summary warning dangerous when you notice any of the unusual conditions listed below, immediately terminate operation and disconnect the power cable. You are covered by the ebay money back guarantee if you receive an item that is not as described in the listing. The chroma 1102111021l are the most costeffective digital lcr meters, providing 100hz, 120hz, 1khz, and 10khz test frequencies for the 11021 and 1khz, 10khz, 40khz, 50khz test frequencies for the 11021l. Lc100adigital lc meter inductance capacitance meter user manual rev. Do not discharge static electricity to the lcr 800. This lcr meter is a 19999 9999 counts dual display, high accuracy lcr meter, which could measure inductance capacitance resistance with secondary parameters including dissipation factor d, quality factor q, phase angle, equivalent series parallel resistance esr or rp. Lc100adigital lc meter inductance capacitance meter. This allows the user to measure the lcr components in auto lcr mode without having to select the type of measurement.
This lcr meter can transfer data to a pc via a standard, fully isolated, optical irusb interface. A range of easy to use lcr meters with comprehensive measurement functions. It can be used to measure inductance, capacitance, resistance, quality factor q, dissipation factor d, phase angle, equivalent series and equivalent parallel resistance. View and download lutron electronics lcr9184 operation manual online. View and download deree de5000 instruction manual online. View and download lutron electronics lcr 9184 operation manual online. Instruction manual dual display lcr meter de5000, a website. The probe assembly provided with the product are for use with meter power requirements. With the u1730 series, you can perform quick, basic lcr measurements at your convenience, without burning a hole in your pocket. It measures in true 4wire kelvin mode and rivals the capabilities and options of many of its bench counterparts. Next came the lcr meter itself in a thick plastic bag.
De5000 portable, fullfeatured lcr meter user and service. Electronic page numbers original page numbers 23, 24, etc. Keysights handheld capacitance meters and portable lcr meters enable you to perform quick, basic lcr measurements at your convenience. Small problem and fix of eevblog user with its recent deree 5000. Check out the proskit mt5211 3 12 digit digital lcr multimeter as good repplacement. Acompatible new de5000 handheld lcr meter with tl21 tl. Wayne kerr electronics products 4300 series lcr meters. The meter is safetycertified in compliance with en61010 iec 10101 installation category ii cat. Better yet, the battery lasts up to 16 hours, ideal for testing on the go. Buy de5000 handheld lcr meter discontinued replaced by de6000. The de5000 is a portable, highperformance lcr meter that is full featured yet cost effective. Two test mode enables consecutive measurements to be made with two different instrument parameters set. U1700 series handheld capacitance and lcr meters keysight. Bk 878b 40,000 count dual display handheld lcr meter.
It also features a sorting mode, allowing users to quickly sort components. Comparison lcr 916 vs u1733c normal model name lcr 916 agilent u1733c main display 20,000 count 20,000 count analog bargraph displayanalog bargraph display 46 segments46 segments 25 segments25 segments auto backlit, dual display dual display only auto selection on lcr testing simple user interface operationsimple user interface operation. When i received it, it would not turn on with the power button. I compared capacitance measurements i got from the de5000 with readings from a calibrated fluke 87v and they were comparable. Please read this instruction manual before using the meter and keep it. Lcr meters and impedence measurement products on sale at.
Agilent e4980a precision lcr meter users guide second edition firmware revisions this manual applies directly to instruments that have the firmware revision a. Lcr6000 series user manual i safety summary warning dangerous when you notice any of the unusual conditions listed below, immediately terminate operation and disconnect the power cable. To accommodate various test requirements, the de6000 handheld lcr meter offers selectable test frequencies. Lcr 800 user manual 6 safety guidelines general guideline caution do not place any heavy object on the lcr 800. If you continue to operate without repairing the instrument, there. I discovered that if i removed the battery and put it back in it powered up immediately, and seemed to work properly. De5000 portable, fullfeatured lcr meter user and service manual. Agilent 4285a precision lcr meter maintenance manual.
Dual handheld lcr meter th2822th2822ath2822c instruction manual. I discovered that if i removed the battery and put it back in it powered up. This wasnt a definitive test of the de5000s capability. Otherwise, the protection provided by the meter may be impaired. The de6000 handheld lcr meter has automatic impedance selection. The liquid controls lectrocount lcrii is a microprocessorbased electronic meter register available in a division 1 or a division 2 enclosure. Acompatible new de5000 handheld lcr meter with tl21 tl22. Deree lcr meter products are manufactured according to international standards. Precisely measure inductance, caacitance, resistance. The sortingmode could help the user to make a quick sort for a bunch of components. Agilent 4285a precision lcr meter including option 001, 002, 201, 202, 301 maintenance manual serial numbers this manual applies directly to instruments whose serial number prefix is 3009j, and whose rombased firmware is version 01. Lcr 914915916 user manual 3 meter description front panel illustration 1. Its a long lasting high performing, excellent accuracy proving esr meter which also low budget esr meter you will not get such quality with this price.
Describe your experience with the de5000 lcresr meter and tell us why you give it the rating you did required. Precision lcr meter lcr800 user manual gw instek part no. Avoid severe impact or rough handling that leads to damaging the lcr 800. For more electronics, woodworking and rc scale building projects, visit. Please contact the gwinstek service center representative for repair of the instrument. Lcr ii overview this manual provides instructions for the initial setup, the calibration, and the operation of lectrocount lcr ii sof tware, also known as sr260 firmware. The liquid controls lectrocount lcr ii is a microprocessorbased electronic meter register available in a division 1 or a division 2 enclosure. Discontinued affordable handheld lcr meter from mastech.